32.2.3. Setting Ethernet parameters
On order to establish the connection with EDYTOR WPW through
Ethernet interface follow the remarks below:
Power up the scale and run the EDYTOR WPW program,
Connect the scale to a computer/switch using a PT0017 or PT0014
cable (depending on the Ethernet module on board – see ch. 27.1.2),
Set the port for communication with a computer – parameter
<P3.1.1 COMP. PORT> set to Ethernet (see ch. 15.1.1),
Set parameters from the <P2.4 ETHERNET> group (see ch. 14.2):
Parameter <P2.4.1 WORK MODE> should be set to SERVER,
Parameters <P2.4.2 IP ADDRESS>, <P2.4.3 SUBNET MASK>,
<P2.4.4 GATEWAY> should be set according to the network
supervisor directions,
<P2.4.5 LOCAL PORT> set the same as in the computer
program (in networks some ports can be taken),
Parameter <P2.4.8 TIMEOUT> set to 0 in order to prevent
breaking connection.
Press the „Settings” button: