22.4. Using formulas in weighing
In activating FORMULATION mode, depending on settings, user can move to
formula making process either on selecting a formulation from corresponding
database or weigh a mixture “manually”.
Preparing mixtures is carried out by:
Preparing a formulation that is not saved in the Database of Formulas
i.e. “manually”,
Preparing a formulation that is saved in the Database of Formulas,
Preparing multiple repetitions of a formulation that is saved in the
Database of Formulas multiplier function,
Preparing a formulation that is saved in the Database of Formulas, with
determining target mass of complete formulation.
Caution:
Using the above options requires enabling corresponding quick access keys in the
bottom bar and setting corresponding options in the formulation mode.
On selecting a formulation, weigh each of its ingredients. On stabilization of
each measurement result press < > key. Mass of each ingredient after
pressing < > is zeroed, i.e. it is accepted for the total mass of the
formulation.
Pressing < > key cancels the formula making process. If pressed, enables
selecting another formulation to making process.
PROCEDURE 1Preparing a formulation that is not saved in the Database
of Formulas i.e. “manually”.
Follow hints and commands displayed by the balance’s software
Press < Formulation without a name> key in the quick access key
bottom bar,
Give name to the new formulation,
The software automatically skips to selecting ingredients of a formulation,
Select an ingredient (new or from database of products),
The software returns to the main window,
Weigh set quantity of an ingredient,
Accept process by pressing < > key,
The software moves to selecting the following ingredient,
Proceed as previously to weigh all required ingredients of a formulation,
After weighing the last ingredient, select one of below options:
<Save and close> - carried out formula making process is saved in the
database of formulation reports and automatically completed,
<Close> - carried out formula making process is completed without
saving a final report in the database of formulation reports,
On selecting one of above options, the software finishes formula making
process and returns to displaying the main window of Formulation mode.